Service Literature

G40UH(X) series units are mid−efficiency gas furnaces

used for upflow or horizontal applications only, manufac-

tured with Lennox Duralok Plus heat exchangers formed of

aluminized steel. G40UH(X) units are available in heating

capacities of 44,000 to 154,000 Btuh and cooling applica-

tions up to 5 tons. Refer to Engineering Handbook for prop-

er sizing.

Units are factory equipped for use with natural gas. Kits are

available for conversion to LPG operation. G40UH(X) model

units are equipped with a hot surface ignition system. The

G40UH(X) unit meets the California Nitrogen Oxides (NO

Standards and California Seasonal Efficiency requirements.

All units use a redundant gas valve to assure safety shut−off

as required by C.S.A.

All specifications in this manual are subject to change. Pro-

cedures outlined in this manual are presented as a recom-

mendation only and do not supersede or replace local or

state codes. In the absence of local or state codes, the

guidelines and procedures outlined in this manual (except

where noted) are recommended only and do not constitute

code.

TABLE OF CONTENTS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . .

II Installation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

III Start Up

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

IV Heating System Service Checks

V Typical Operating Characteristics

VI Maintenance

. . . . . . . . . . . . . . . . . . . . . . . . . .

VII Wiring and Sequence of Operation

VIII SureLight Troubleshooting Guide

Corp. 0006−L3

Revised 09−2006

)

x

Page 2

Page 4

Page 13

Page 14

Page 16

Page 24

Page 24

. . . . . . . . .

Page 24

. . . . . . . . .

Page 28

Page 28

. . . . . .

Page 30

. . . . . . .

Page 41

Page 1

IMPORTANT

Improper installation, adjustment, alteration, service

or maintenance can cause property damage, person-

al injury or loss of life. Installation and service must

be performed by a qualified installer, service agency

or the gas supplier.

WARNING

Electric shock hazard. Can cause injury

or death. Before attempting to perform

any service or maintenance, turn the

Electrical power to unit OFF at discon-

nect switch(es). Unit may have multiple

power supplies.

WARNING

Sharp edges.

Be careful when servicing unit to avoid sharp edges

which may result in personal injury.

G40UH(X)

© 2000 Lennox Industries Inc.

LENNOX G40UH(X) UNIT INFORMATION Pdf Download (2024)

FAQs

How do I know what tonnage my Lennox unit is? ›

You may find the answer on your current unit. Find your condensing unit and search for a data plaque or sticker on the side. You should see a model number and a string of numerals and letters. There should also be an even, two-digit number – which indicates the AC tonnage of the unit.

Where is the secondary limit switch on a Lennox G40UH? ›

The primary limit G40UH(X) units is located in the heating vestibule panel. The secondary limit is located in the blower compartment in the back side of the blower housing.

What type of Lennox system do I have? ›

The model is identified by a "model number" which is stamped on the unit nameplate or rating plate. On residential gas and oil furnaces this identification plate is located on the inside of cabinet near the vestibule panel. On other Lennox products the plate is mounted on the outside of unit.

What size is my Lennox air conditioner? ›

The size of your Lennox Air Conditioner can be determined from the model number of the unit. The model number (M/N) can be located outside on the panel along with the serial number. For Example: A unit with a model number of 10ACB42-1P lists the unit's capacity that it provides to the living space.

How do I tell what ton my unit is? ›

Simply divide the BTUs by 12,000 to calculate the tonnage of your unit. For example, if your air conditioner is 36,000 BTUs, you have a 3 ton unit. Some manufacturers bury tonnage or BTU information in their model numbers. Look for an even, two-digit number between 18 and 60.

How to read Lennox serial numbers? ›

Modern Lennox system serial numbers contain 4 numbers followed by a letter. The first 2 numbers represent the factory where they were manufactured, the second 2 numbers are the year and the letter is the month where A is January, B is February, etc. An example would be 5800A12345.

Where is the Lennox limit switch reset? ›

Examine your furnace and look for a raised button or switch to the right of the ignition control box (or the “ Lennox limit switch reset"). Press and release the limit control switch to rest your Lennox furnace.

What does a Lennox limit switch do? ›

A furnace limit switch is a component of a forced-air furnace that is responsible for turning on the furnace blower once the desired heat has been met inside the furnace. Without a functioning furnace limit switch, a furnace would not be able to regulate the temperature in conjunction with a thermostat.

How do I know if my limit switch is bad on my furnace? ›

Signs of a faulty furnace limit switch include the furnace not turning on or off, inconsistent temperature control, or overheating. If you suspect a malfunctioning limit switch, there are troubleshooting steps you can take. First, check if the switch is stuck or dirty and clean it if necessary.

How long should a Lennox HVAC system last? ›

How long does Lennox air conditioner last? Air conditioners and heat pumps last an average of 10 to 15 years, while furnaces have a life span of around 15 to 20 years.

What is the lawsuit against Lennox air conditioner coils? ›

What is this lawsuit about? The Plaintiffs claim that Lennox manufactures and sells air conditioning systems and heat pump systems, including air handlers and Packaged Units, containing defective evaporator coils that corrode and leak refrigerant.

What are the different levels of Lennox? ›

Lennox Products. Like many companies, Lennox divides its products into three series: Signature, Elite, and Merit. The Dave Lennox Signature Collection series features its most energy-efficient models and incorporates its latest technologies. Not surprisingly, these are Lennox's most expensive units.

Is Lennox better than Trane? ›

Energy Efficiency

In a head-to-head comparison of Trane vs. Lennox, Lennox wins in the energy efficiency category. Lennox units come in a range of SEER ratings from 13-28. That 13 SEER rating is being retired to comply with new minimum standards, but a rating of 28 is the best the industry has to offer.

What is a good SEER rating? ›

If you are looking for a high-efficiency air conditioner, then you should look for a unit with a SEER rating of 17 or higher. However, if you are more concerned with unit affordability, then a SEER rating of 14 or 15 may be more suitable for you.

Are Lennox AC units good? ›

Lennox® air conditioners are amongst the quietest and most energy efficient units on the market. Delivering perfectly precise comfort control, Lennox air conditioners continually make small adjustments in fan speed and cooling output to hold your temperature exactly where you want it.

How do I calculate the tonnage of my home air conditioner? ›

To estimate your AC tonnage needs, multiply the number of square feet you're cooling times 25. This equals the total number of BTUs you need to adequately cool your space. Next, divide that number by 12,000 to determine the tonnage capability you need in your new air conditioning unit.

How do I know what tonnage my furnace is? ›

You may be able to determine the tonnage of your HVAC unit by simply reading the manufacturer's label on your system's outdoor unit. However, most manufacturers don't list tonnage and instead, list BTUs. Converting BTUs to tonnage can be done by simply dividing the BTUs by 12,000.

How many tons is Lennox ML14XC1? ›

ML14XC1 - 1.5 to 5 Ton Air Conditioner / Page 5

Heavy gauge steel cabinet with five station metal wash process. Louvered heavy gauge steel panels surround unit on all four sides to prevent damage to the coil.

How many tons is 18,000 BTU? ›

1.5 Ton

Top Articles
Latest Posts
Article information

Author: Clemencia Bogisich Ret

Last Updated:

Views: 6465

Rating: 5 / 5 (60 voted)

Reviews: 91% of readers found this page helpful

Author information

Name: Clemencia Bogisich Ret

Birthday: 2001-07-17

Address: Suite 794 53887 Geri Spring, West Cristentown, KY 54855

Phone: +5934435460663

Job: Central Hospitality Director

Hobby: Yoga, Electronics, Rafting, Lockpicking, Inline skating, Puzzles, scrapbook

Introduction: My name is Clemencia Bogisich Ret, I am a super, outstanding, graceful, friendly, vast, comfortable, agreeable person who loves writing and wants to share my knowledge and understanding with you.